About this calculator

Collapse and internal yield ratings for casing and tubing, checked against the differential a given operation imposes. The collapse side is not one formula but four regimes selected by slenderness, and picking the wrong regime is the usual way a rating comes out optimistic.

  • Yield, plastic, transition and elastic collapse regimes
  • Internal yield with a wall tolerance allowance
  • Design factors applied and shown, never folded into the rating

Method

Needs review

Field units

Pb = 0.875 × 2 × Yp × t ÷ D Pc = one of four regimes, selected by D/t and Yp

Symbols

D
Outside diameter · in
t
Nominal wall thickness · in
Yp
Specified minimum yield strength · psi
ΔP
Applied differential · psi
Pc
Collapse rating · psi
Pb
Internal yield rating · psi
SF
Safety factor · —

Assumptions

  • The 0.875 in the burst relation is the API 12.5% wall tolerance allowance. The Barlow form is a thin-wall approximation on the outside diameter; for heavy-wall pipe (low D/t) it departs from a thick-wall (Lamé) or ductile-rupture check, so treat it as the API rating, not as the pressure at which that pipe fails.
  • The four collapse regimes and their empirical constants come from API TR 5C3. The constants are not reproduced here and this entry is marked for review until they are checked against the standard.
  • Ratings are for the pipe body. Connections are rated separately by the manufacturer and are frequently the limit.
  • Axial load reduces collapse resistance. A biaxial or triaxial check is a different calculation from either of these.

Reference

API TR 5C3 / ISO 10400. Constants to be taken from the standard, not from this page.

Worked example

Needs review

5½" 17 lb/ft L-80 tubing, checked against a treating pressure.

Given

D
5.5 in
t
0.304 in
Yp
80,000 psi
ΔP
5,200 psi

Working

  1. 01Burst rating
    0.875 × 2 × 80,000 × 0.304 ÷ 5.57,738 psi
  2. 02Safety factor
    7,738 ÷ 5,2001.49 —

Worth knowing

Burst only. The 0.875 is the API wall tolerance — the rating is taken on the thinnest wall a joint is permitted to have, not the nominal one, and dropping it would overstate this string by 1,105 psi. Collapse is a different question with four regimes and constants from API TR 5C3, which are not reproduced here, so there is no collapse figure in this example.

The arithmetic above is checkable. The relation it works is not yet: needs a completion engineer, or tables this repository does not hold. Treat the relation as an outline, not as a figure to work from.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Collapse and burst calculator
SymbolQuantityFieldSI
DOutside diameterinmm
tNominal wall thicknessinmm
YpSpecified minimum yield strengthpsiMPa
ΔPApplied differentialpsikPa

Outputs

Outputs from the Collapse and burst calculator
SymbolQuantityFieldSI
PcCollapse ratingpsikPa
PbInternal yield ratingpsikPa
SFSafety factor——

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Tubulars

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Tubulars

Tubing forces

Length change and packer loads through the four effects

Tubing movement and packer load through the classical four effects — piston, buckling, ballooning and temperature — for the pressure and temperature changes a completion sees between running, testing, stimulating and producing. The temperature term alone is often the largest and the one most often left out.

Needs review

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.