Skip to content
All calculators
LoggingPlannedSourced

Depth correlation

CCL and gamma ray tied back to a reference log

About this calculator

Depth correction for a cased-hole run: matching casing collars and gamma-ray markers against the reference log, and carrying the correction through to a perforating or setting depth. The number that matters is the shift applied and the confidence in it, which is why both will be reported rather than a single corrected depth.

  • Collar count and spacing against a tally
  • Gamma-ray marker tie-in with the applied shift stated
  • Stretch and temperature corrections listed separately

Method

Sourced

Field units

Δd = dref − dlog dc = dlog + Δd

Symbols

dlog
Depth on this run · ft
dref
Depth on the reference log · ft
Lj
Casing joint length · ft
Δd
Applied depth shift · ft
dc
Corrected depth · ft

Assumptions

  • The subtraction is trivial; the method is not. Which markers are matched, and whether the shift is constant or depth-dependent, is an interpretation made by the engineer on the unit.
  • The reference log is itself only as good as its own depth control. A correlation ties two logs together — it does not establish truth.
  • Cable stretch and thermal expansion are handled as separate corrections, not folded into the tie-in shift.
  • A collar count assumes the tally is right. A short joint changes the count without changing the log.

Reference

Standard cased-hole logging practice.

Worked example

Sourced

A cased-hole run tied back to the completion log on a 15 ft marker joint, before setting a plug read at 9,210.0 ft on this run.

Given

dref
8,452.0 ft
dlog
8,447.5 ft
Lj
15.0 ft

Working

  1. 01Depth shift
    8,452.0 − 8,447.54.5 ft
  2. 02Corrected setting depth
    9,210.0 + 4.59,214.5 ft

Worth knowing

The shift is applied to everything on the run, not just to the tie-in point — a correction picked at one collar and used at one depth is not a correction, it is a coincidence. The 15 ft marker joint is what makes the tie unambiguous; on a string of uniform 31–32 ft joints there would be nothing to distinguish one collar from the next.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Depth correlation calculator
SymbolQuantityFieldSI
dlogDepth on this runftm
drefDepth on the reference logftm
LjCasing joint lengthftm

Outputs

Outputs from the Depth correlation calculator
SymbolQuantityFieldSI
ΔdApplied depth shiftftm
dcCorrected depthftm

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Logging

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Logging

Wireline stretch

Cable stretch, weak point and safe pull

Elastic stretch of a wireline cable under toolstring weight and overpull, and the tension at which the weak point is designed to part. Stretch is a depth-control problem and weak point is a safety one, but both come off the same tension, which is why they belong on one page.

Needs review

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.