Skip to content
All calculators
WellborePlannedRe-derived

Several strings in one hole

Capacity when two strings share an annulus at the same depth

About this calculator

The capacity that is left when two or more strings occupy the same depth — a dual completion, a velocity string run alongside a tubing, or control lines and encapsulation taken off the annulus rather than ignored. AT THE SAME DEPTH is the whole of the difference: with one string at any given depth the annular area is π/4(D² − d²), and that single-string case is not what this entry covers. Two or more at once makes it π/4(D² − Σdᵢ²), which is what this entry adds.

  • Annular capacity with two or more strings at the same depth
  • Control lines and encapsulation subtracted rather than ignored
  • Strings stacked down a well — tapered, or crossing a shoe — are a single string at each depth, and are summed interval by interval rather than here

Method

Re-derived

Field units

Cann = (D² − Σdᵢ²) ÷ 1029.4 V = Cann × L

Symbols

D
Hole or casing inside diameter · in
dᵢ
Outside diameter of each string · in
L
Interval length · ft
Cann
Annular capacity · bbl/ft
V
Volume · bbl

Assumptions

  • The 1029.4 is a rounding and the exact ratio is carried instead: a barrel is 42 × 231 = 9702 in³, so (π/4) × 12 ÷ 9702 = 1 ÷ 1029.414172. The two disagree in the sixth figure. The barrel itself is 158.987294928 litres exactly.
  • Nominal diameters. Casing drift is smaller than inside diameter, and an open hole is not the bit size.
  • Volume does not depend on where the strings sit. An eccentric string has the same volume and the same flow area as a concentric one, but very different flow behaviour and friction.
  • Couplings and control lines are ignored unless entered separately.

Reference

Definitional — derived from the US barrel.

Worked example

Re-derived

A dual completion: two 2⅞" strings side by side inside 9⅝" 47 lb/ft casing, to 9,200 ft.

Given

D
8.681 in
dᵢ
2.875 / 2.875 in
L
9,200 ft

Working

  1. 01Annular capacity
    (8.681² − 2 × 2.875²) ÷ 1029.41420.05715 bbl/ft
  2. 02Annular volume
    0.05715 × 9,200525.8 bbl

Worth knowing

Leaving the second string out — working it as one string in the casing — gives 599.6 bbl, 74 bbl more than the hole actually holds. And the 8.681 is the published internal diameter for that weight, not the 9.625 on the tally: using the outside diameter inflates this annulus to 680.2 bbl, nearly 30% and about 154 bbl too much.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Several strings in one hole calculator
SymbolQuantityFieldSI
DHole or casing inside diameterinin
dᵢOutside diameter of each stringinin
LInterval lengthftm

Outputs

Outputs from the Several strings in one hole calculator
SymbolQuantityFieldSI
CannAnnular capacitybbl/ftm³/m
VVolumebblm³

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Wellbore

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Wellbore

Abandonment plugs

Slurry volume, plug length and the balance point

Cement volumes for plug and abandonment: slurry for a nominated plug length, spacer either side, and the balance point for a balanced plug. Regulator-driven work where the plug length is prescribed, so the question is usually volume for a given length rather than the reverse.

Sourced

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.