Skip to content
All calculators
FluidsPlannedRe-derived

Displacement and pills

Volumes, strokes and where the interface actually is

About this calculator

Displacement volumes and pump strokes for a full or partial circulation, and placement of a pill at a chosen depth. The useful part is the running position of the interface: knowing the total is not the same as knowing where the top of the spacer is after 340 strokes.

  • Strokes to bit, to surface and to any nominated depth
  • Pill volume and placement including balanced plugs
  • Interface position tracked through the circulation

Method

Re-derived

Field units

V = C × L N = V ÷ Vp

Symbols

Cann
Annular capacity · bbl/ft
Ctbg
Tubing capacity · bbl/ft
L
Interval length · ft
Vp
Pump output per stroke · bbl/stk
V
Volume · bbl
N
Strokes · stk
d
Interface depth · ft

Assumptions

  • Volume arithmetic is exact. Pump output per stroke is not — it depends on volumetric efficiency, which is measured rather than calculated and drifts as a pump wears.
  • Capacities assume nominal internal diameters. Wall loss, scale and liner wear all change them.
  • Incompressible fluid and no losses to formation. Any returns deficit invalidates the interface position.
  • A balanced plug assumes the same fluid on both sides at the same height, which is what makes it balance.

Reference

Definitional, from pipe and annular capacity.

Worked example

Re-derived

Displacing 2⅞" 6.5 lb/ft tubing to a brine, counting strokes to the end of the tubing.

Given

Ctbg
0.00579 bbl/ft
L
9,400 ft
Vp
0.1015 bbl/stk

Working

  1. 01Volume to the end of the tubing
    0.00579 × 9,40054.43 bbl
  2. 02Strokes
    54.43 ÷ 0.1015536 stk

Worth knowing

This is the tubing only. Bringing the same interface back up the annulus is a second volume on a different capacity, and adding one and forgetting the other is the commonest displacement error there is.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Displacement and pills calculator
SymbolQuantityFieldSI
CannAnnular capacitybbl/ftm³/m
CtbgTubing capacitybbl/ftm³/m
LInterval lengthftm
VpPump output per strokebbl/stkm³/stk

Outputs

Outputs from the Displacement and pills calculator
SymbolQuantityFieldSI
VVolumebblm³
NStrokesstk—
dInterface depthftm

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Fluids

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Fluids

Fluid column

Layered columns and the U-tube between them

A well is rarely full of one fluid. This handles the stack: brine over mud over cement, a gas cap, a spacer in the middle, and works out what the column exerts at any depth and where the two sides of a U-tube come to rest. The answer to "will it flow back when I open it" is a column balance, not a single hydrostatic.

Re-derived
Planned

Fluids

Brine density

Density at temperature and pressure, and the crystallisation point

Completion brines are not incompressible and their density is quoted at surface conditions. At depth they are hotter and under pressure, and a column designed at surface density can end up underbalanced. This also carries the crystallisation temperature, which is the number that decides whether a brine can sit on surface overnight in winter.

Needs review

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.