Abandonment plugs

Slurry volume, plug length and the balance point

About this calculator

Cement volumes for plug and abandonment: slurry for a nominated plug length, spacer either side, and the balance point for a balanced plug. Regulator-driven work where the plug length is prescribed, so the question is usually volume for a given length rather than the reverse.

  • Slurry and spacer volumes for a nominated plug length
  • Balanced plug calculation with the displacement to leave it in place
  • Excess allowance stated separately rather than folded in

Method

Sourced

Field units

Vs = C × Lp × (1 + e) n = Vs ÷ Y

Symbols

C
Capacity at plug depth · bbl/ft
Lp
Required plug length · ft
Y
Slurry yield · ft³/sk
e
Excess · —
Vs
Slurry volume · bbl
n
Sacks of cement · sk
Vd
Displacement volume · bbl

Assumptions

  • The volume arithmetic is exact. Slurry yield is a laboratory value for a specific blend and mix water ratio, and is quoted from the cement design rather than derived.
  • Excess is an allowance for hole enlargement, not a safety factor. In cased hole it is small; across an open-hole section it is a guess informed by a caliper.
  • A balanced plug assumes equal fluid heights inside and outside the stinger at the moment displacement stops.
  • Plug length, setting depth and verification requirements are set by the regulator for the jurisdiction, and are not a calculation.

Reference

Standard cementing practice; see API Bulletin E3 (well abandonment and inactive well practices) and the abandonment regulations of the jurisdiction, which take precedence.

Worked example

Sourced

A 500 ft balanced plug in 7" 26 lb/ft casing, with a tenth excess.

Given

C
0.0383 bbl/ft
Lp
500 ft
e
0.10 —
Y
1.18 ft³/sk

Working

  1. 01Slurry volume
    0.0383 × 500 × 1.1021.065 bbl
  2. 02In cubic feet
    21.065 × 9702 ÷ 1728118.27 ft³
  3. 03Sacks
    118.27 ÷ 1.18100.2 sk

Worth knowing

The 0.0383 is 6.276² ÷ 1029.4142, the published internal diameter for that weight. The barrel-to-cubic-foot step is exact — 42 US gallons is 9702 in³ by definition — but the yield is not: 1.18 ft³/sk is a slurry design figure from the service company, and a different design moves the sack count without moving anything else here. In practice the count is rounded up to whole sacks.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Abandonment plugs calculator
SymbolQuantityFieldSINotes
CCapacity at plug depthbbl/ftm³/m
LpRequired plug lengthftm
YSlurry yieldft³/skm³/t
eExcess——A fraction of the gauge volume: 10% is entered as 0.10.

Outputs

Outputs from the Abandonment plugs calculator
SymbolQuantityFieldSI
VsSlurry volumebblm³
nSacks of cementsk—
VdDisplacement volumebblm³

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Wellbore

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Wellbore

Several strings in one hole

Capacity when two strings share an annulus at the same depth

The capacity that is left when two or more strings occupy the same depth — a dual completion, a velocity string run alongside a tubing, or control lines and encapsulation taken off the annulus rather than ignored. AT THE SAME DEPTH is the whole of the difference: with one string at any given depth the annular area is π/4(D² − d²), and that single-string case is not what this entry covers. Two or more at once makes it π/4(D² − Σdᵢ²), which is what this entry adds.

Re-derived

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.