Skip to content
All calculators
PressurePlannedSourced

Bottomhole pressure

Surface pressure carried to depth, gas or liquid

About this calculator

Converts a measured surface pressure into a bottomhole pressure, and back. For a liquid column that is an addition; for a gas column it is not, because the gas compresses under its own weight and the gradient changes with depth. Treating a gas column as though it had a constant gradient is a well-control error, so the two cases will be separate entries rather than one with a checkbox.

  • Liquid and gas columns handled as different problems
  • Average temperature and compressibility for the gas case
  • Reports the gradient it used, not just the answer

Method

Sourced

Field units

Liquid: BHP = Ps + 0.052 × MW × TVD Gas: BHP = Ps × exp(0.01875 × γg × TVD ÷ (T̄ × z̄))

Symbols

Ps
Surface pressure · psi
TVD
True vertical depth · ft
γg
Gas specific gravity · —
T̄
Average column temperature · °R
z̄
Average compressibility factor · —
BHP
Bottomhole pressure · psi
G
Effective gradient · psi/ft

Assumptions

  • The gas form is the average temperature and compressibility method. The 0.01875 constant expects depth in feet and temperature in degrees Rankine, and the pressures in it are absolute — the ratio BHP ÷ Ps is only right in psia.
  • z̄ is evaluated at the average pressure and temperature of the column, which makes the calculation iterative — a single pass with an assumed z̄ will be close but is not the answer.
  • A static column. No flow, no friction, no slip.
  • Dry gas of uniform composition. A wet or condensate-laden column is not this relation.

Reference

Average temperature and z-factor method — standard gas-well deliverability practice.

Worked example

Sourced

A shut-in gas well, Example Well B, taken from surface to depth.

Given

Ps
3,250 psia
TVD
9,800 ft
γg
0.65 —
T̄
610 °R
z̄
0.92 —

Working

  1. 01Exponent
    0.01875 × 0.65 × 9,800 ÷ (610 × 0.92)0.21283 —
  2. 02Bottomhole pressure
    3,250 × e^0.212834,020.80 psia

Worth knowing

The gas case, because it is the one that goes wrong. A liquid column of the same surface pressure and depth would add a fixed gradient; a gas column multiplies it, so the answer is sensitive to z̄ — which is read off a chart rather than derived, and is the one figure here a reader has to supply from somewhere else.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Bottomhole pressure calculator
SymbolQuantityFieldSINotes
PsSurface pressurepsikPaGauge for the liquid form. Absolute (psia) for the gas form: add atmospheric, 14.696 psi at sea level, to a gauge reading first.
TVDTrue vertical depthftmVertical, not along-hole. This is the single commonest error in the whole set.
γgGas specific gravity——Air = 1.0
T̄Average column temperature°RK
z̄Average compressibility factor——

Outputs

Outputs from the Bottomhole pressure calculator
SymbolQuantityFieldSI
BHPBottomhole pressurepsikPa
GEffective gradientpsi/ftkPa/m

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Pressure

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Pressure

Hydrostatic pressure

Column pressure at depth, and the margin either side of it

The first number on almost every cased-hole programme: what a static column of one fluid exerts at a given true vertical depth. It will take density in any of the units the industry actually writes it in, and give back the pressure, the gradient and the equivalent mud weight together, because those three are the same statement and quoting one without the others is how a margin gets misread.

Re-derived
Planned

Pressure

Kill sheet

Kill weight, circulating pressures and the pressure schedule

The arithmetic behind a driller's or wait-and-weight kill: kill weight from shut-in drillpipe pressure, initial and final circulating pressure, and the pressure step-down schedule from surface to bit. It is a small set of relations that has to be right under time pressure, which is exactly the case for having it laid out rather than done on a whiteboard.

Re-derived
Planned

Pressure

Formation integrity

LOT and FIT reduced to a working pressure limit

Turns a leak-off or formation integrity test into the two numbers that get used afterwards: the equivalent mud weight the shoe will hold, and the maximum allowable annular surface pressure at the current mud weight. MAASP moves every time the mud weight does, which is the part most easily left stale on a drilling report.

Re-derived

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.