Skip to content
All calculators
PressurePlannedRe-derived

Formation integrity

LOT and FIT reduced to a working pressure limit

About this calculator

Turns a leak-off or formation integrity test into the two numbers that get used afterwards: the equivalent mud weight the shoe will hold, and the maximum allowable annular surface pressure at the current mud weight. MAASP moves every time the mud weight does, which is the part most easily left stale on a drilling report.

  • Leak-off pressure to equivalent mud weight at the shoe
  • MAASP at the current density, recomputed when it changes
  • Kick tolerance against a stated influx height

Method

Re-derived

Field units

EMWlot = MWt + Plot ÷ (0.052 × TVDs) MAASP = (EMWlot − MWc) × 0.052 × TVDs

Symbols

Plot
Leak-off surface pressure · psi
MWt
Mud weight at test · ppg
TVDs
Shoe true vertical depth · ft
MWc
Current mud weight · ppg
EMWlot
Leak-off equivalent mud weight · ppg
MAASP
Max allowable annular surface pressure · psi

Assumptions

  • Again the 0.052 identity rearranged, so the arithmetic is exact. The judgement is in reading the leak-off point off the plot, which no calculator can do for you.
  • The shoe is the weakest point in the open hole. If a formation below it is weaker, MAASP computed at the shoe is optimistic.
  • A leak-off test and a formation integrity test are not the same measurement — an FIT is stopped before leak-off, so it gives a lower bound rather than the formation strength.
  • MAASP is invalidated the moment the annulus is no longer full of the stated mud weight.

Reference

Standard well control practice; see also API RP 59 for terminology.

Worked example

Re-derived

A leak-off test at the 9⅝" shoe, reduced to a working limit.

Given

Plot
1,250 psi
MWt
9.8 ppg
TVDs
6,800 ft
MWc
10.4 ppg

Working

  1. 01Equivalent mud weight at leak-off
    9.8 + 1,250 ÷ (12 ÷ 231 × 6,800)13.34 ppg
  2. 02MAASP at the current weight
    1,250 − (10.4 − 9.8) × 12 ÷ 231 × 6,8001,038 psi

Worth knowing

MAASP moves every time the mud weight does, which is the point of carrying it as a second output rather than quoting the leak-off figure alone. At 10.4 ppg the shoe has 1,038 psi in hand; at 11.4 it has under 700. The working above is the same relation rearranged — (EMWlot − MWc) × 0.0519… × TVDs — written so that a hand check does not pick up the rounding in the 13.34; worked from the rounded EMW it comes out at 1,039.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Formation integrity calculator
SymbolQuantityFieldSI
PlotLeak-off surface pressurepsikPa
MWtMud weight at testppgkg/m³
TVDsShoe true vertical depthftm
MWcCurrent mud weightppgkg/m³

Outputs

Outputs from the Formation integrity calculator
SymbolQuantityFieldSI
EMWlotLeak-off equivalent mud weightppgkg/m³
MAASPMax allowable annular surface pressurepsikPa

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Pressure

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Pressure

Hydrostatic pressure

Column pressure at depth, and the margin either side of it

The first number on almost every cased-hole programme: what a static column of one fluid exerts at a given true vertical depth. It will take density in any of the units the industry actually writes it in, and give back the pressure, the gradient and the equivalent mud weight together, because those three are the same statement and quoting one without the others is how a margin gets misread.

Re-derived
Planned

Pressure

Bottomhole pressure

Surface pressure carried to depth, gas or liquid

Converts a measured surface pressure into a bottomhole pressure, and back. For a liquid column that is an addition; for a gas column it is not, because the gas compresses under its own weight and the gradient changes with depth. Treating a gas column as though it had a constant gradient is a well-control error, so the two cases will be separate entries rather than one with a checkbox.

Sourced
Planned

Pressure

Kill sheet

Kill weight, circulating pressures and the pressure schedule

The arithmetic behind a driller's or wait-and-weight kill: kill weight from shut-in drillpipe pressure, initial and final circulating pressure, and the pressure step-down schedule from surface to bit. It is a small set of relations that has to be right under time pressure, which is exactly the case for having it laid out rather than done on a whiteboard.

Re-derived

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.