Skip to content
All calculators
PressurePlannedRe-derived

Hydrostatic pressure

Column pressure at depth, and the margin either side of it

About this calculator

The first number on almost every cased-hole programme: what a static column of one fluid exerts at a given true vertical depth. It will take density in any of the units the industry actually writes it in, and give back the pressure, the gradient and the equivalent mud weight together, because those three are the same statement and quoting one without the others is how a margin gets misread.

  • Density in ppg, specific gravity, lb/ft³ or kg/m³
  • Pressure, gradient and equivalent mud weight from one entry
  • Overbalance against a stated pore or fracture pressure

Method

Re-derived

Field units

P = 0.052 × MW × TVD

SI

P = ρ × g × h

Symbols

MW
Fluid density · ppg
TVD
True vertical depth · ft
P
Hydrostatic pressure · psi
G
Pressure gradient · psi/ft
EMW
Equivalent mud weight · ppg

Assumptions

  • The exact constant is 12 in/ft ÷ 231 in³/gal = 0.0519480… psi/ft per ppg, and 0.052 is that ratio rounded — a 0.1% overstatement, which is why the calculator will carry the exact ratio and round only for display.
  • The column is static. Any circulation adds friction and the answer becomes ECD, not hydrostatic.
  • The fluid is a single uniform density over the whole interval. Layered columns are the fluid column calculator.
  • Depth is true vertical. Measured depth in a deviated well overstates the pressure.

Reference

Definitional — derived from the US barrel and gallon.

Worked example

Re-derived

Example Well A, checking the column before opening up.

Given

MW
11.2 ppg
TVD
8,450 ft

Working

  1. 01Gradient
    12 ÷ 231 × 11.20.58182 psi/ft
  2. 02Hydrostatic pressure
    0.58182 × 8,4504,916.36 psi

Worth knowing

Worked with 0.052 instead of the exact ratio the same column comes out at 4,921.28 psi — 4.92 psi high. That is the 0.1% the assumptions mention, and it is why the calculator will carry the ratio and round only for display.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Hydrostatic pressure calculator
SymbolQuantityFieldSINotes
MWFluid densityppgkg/m³Also accepted as specific gravity or lb/ft³.
TVDTrue vertical depthftmVertical, not along-hole. This is the single commonest error in the whole set.

Outputs

Outputs from the Hydrostatic pressure calculator
SymbolQuantityFieldSI
PHydrostatic pressurepsikPa
GPressure gradientpsi/ftkPa/m
EMWEquivalent mud weightppgkg/m³

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Pressure

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Pressure

Bottomhole pressure

Surface pressure carried to depth, gas or liquid

Converts a measured surface pressure into a bottomhole pressure, and back. For a liquid column that is an addition; for a gas column it is not, because the gas compresses under its own weight and the gradient changes with depth. Treating a gas column as though it had a constant gradient is a well-control error, so the two cases will be separate entries rather than one with a checkbox.

Sourced
Planned

Pressure

Kill sheet

Kill weight, circulating pressures and the pressure schedule

The arithmetic behind a driller's or wait-and-weight kill: kill weight from shut-in drillpipe pressure, initial and final circulating pressure, and the pressure step-down schedule from surface to bit. It is a small set of relations that has to be right under time pressure, which is exactly the case for having it laid out rather than done on a whiteboard.

Re-derived
Planned

Pressure

Formation integrity

LOT and FIT reduced to a working pressure limit

Turns a leak-off or formation integrity test into the two numbers that get used afterwards: the equivalent mud weight the shoe will hold, and the maximum allowable annular surface pressure at the current mud weight. MAASP moves every time the mud weight does, which is the part most easily left stale on a drilling report.

Re-derived

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.