Skip to content
All calculators
PressurePlannedRe-derived

Kill sheet

Kill weight, circulating pressures and the pressure schedule

About this calculator

The arithmetic behind a driller's or wait-and-weight kill: kill weight from shut-in drillpipe pressure, initial and final circulating pressure, and the pressure step-down schedule from surface to bit. It is a small set of relations that has to be right under time pressure, which is exactly the case for having it laid out rather than done on a whiteboard.

  • Kill weight from SIDPP and true vertical depth
  • Initial and final circulating pressure from a slow-circulate rate
  • Step-down schedule by strokes, printable as a sheet

Method

Re-derived

Field units

KWM = OMW + SIDPP ÷ (0.052 × TVD) ICP = SIDPP + SCRP FCP = SCRP × KWM ÷ OMW

Symbols

OMW
Original mud weight · ppg
SIDPP
Shut-in drillpipe pressure · psi
TVD
True vertical depth · ft
SCRP
Slow circulating rate pressure · psi
KWM
Kill weight mud · ppg
ICP
Initial circulating pressure · psi
FCP
Final circulating pressure · psi

Assumptions

  • The algebra is exact given the inputs — it is the same 0.052 identity rearranged. What is not exact is SIDPP: a gauge reading during an influx is the weak link, not the arithmetic.
  • FCP scales linearly with density, which assumes the pump pressure at slow rate is dominated by density rather than by rheology. At low rates and high viscosity that assumption weakens.
  • A single-bubble influx and a constant bottomhole pressure method.
  • This is arithmetic for a well-control plan, not a well-control procedure. It does not replace a certified kill sheet or the judgement of the person on the brake.

Reference

Standard constant-bottomhole-pressure well control practice.

Worked example

Re-derived

Example Well C, shut in on a kick, working the sheet before the pump comes up.

Given

OMW
12.4 ppg
SIDPP
480 psi
TVD
9,600 ft
SCRP
720 psi

Working

  1. 01Kill weight mud
    12.4 + 480 ÷ (12 ÷ 231 × 9,600)13.36 ppg
  2. 02Initial circulating pressure
    720 + 4801,200 psi
  3. 03Final circulating pressure
    720 × 13.36 ÷ 12.4776 psi

Worth knowing

In practice the kill weight is rounded up to the next tenth — 13.4 — because a mud plant cannot hold two decimal places and rounding down would leave the well underbalanced. The sheet is worked from the rounded figure, not this one.

Preview

A design preview of a calculator that is not built yet. Nothing here is behind a sign-in — there is nothing to sign in to.

Tell us you want this one

Interface

What it takes, and what it gives back.

Field units first, because that is what the programme and the daily report are written in. Where a quantity is dimensionless there is no metric column to fill.

Inputs

Inputs to the Kill sheet calculator
SymbolQuantityFieldSINotes
OMWOriginal mud weightppgkg/m³
SIDPPShut-in drillpipe pressurepsikPa
TVDTrue vertical depthftmVertical, not along-hole. This is the single commonest error in the whole set.
SCRPSlow circulating rate pressurepsikPa

Outputs

Outputs from the Kill sheet calculator
SymbolQuantityFieldSI
KWMKill weight mudppgkg/m³
ICPInitial circulating pressurepsikPa
FCPFinal circulating pressurepsikPa

Scope

When this is the wrong tool.

A right number from the wrong calculator is the failure worth designing against, so each of these names the condition rather than the calculator.

Pressure

Related calculations.

The ones that tend to be done in the same sitting, and that share assumptions with this.

Planned

Pressure

Hydrostatic pressure

Column pressure at depth, and the margin either side of it

The first number on almost every cased-hole programme: what a static column of one fluid exerts at a given true vertical depth. It will take density in any of the units the industry actually writes it in, and give back the pressure, the gradient and the equivalent mud weight together, because those three are the same statement and quoting one without the others is how a margin gets misread.

Re-derived
Planned

Pressure

Bottomhole pressure

Surface pressure carried to depth, gas or liquid

Converts a measured surface pressure into a bottomhole pressure, and back. For a liquid column that is an addition; for a gas column it is not, because the gas compresses under its own weight and the gradient changes with depth. Treating a gas column as though it had a constant gradient is a well-control error, so the two cases will be separate entries rather than one with a checkbox.

Sourced
Planned

Pressure

Formation integrity

LOT and FIT reduced to a working pressure limit

Turns a leak-off or formation integrity test into the two numbers that get used afterwards: the equivalent mud weight the shoe will hold, and the maximum allowable annular surface pressure at the current mud weight. MAASP moves every time the mud weight does, which is the part most easily left stale on a drilling report.

Re-derived

Does this match how you actually work it?

The assumptions above are the part worth arguing with. If one of them does not hold on the wells you run, that changes what gets built and how.